INSTALLATION
ReliefValve
Plug
To Household
Water System Built-in
Check Valve
Tank
Switch
Adapter
From
Weft
Plastic
Pipe
Figure 2 - Typical Installation - Captive Air e
Pressure Tank
o.ockvo,vo
NOTE: _ 1 1/4"
Check Va_e used if
h°dz°ntal piping is _t /Stee_
25. o_more _{ Drive
Pipe
Drive
_'Coupling
Ddven Point
Plastic P
Well Seal
Foot Valve
Dug or Cased Well
Relief
Valve
Priming
To Household
Water System
AVC Port
From
Well
Air Volume
Control Tube Built-in
Check Valve
Figure 3 - Typical Installation - Standard
Pressure Tank
Pump Installation
SEARS jet pumps can be used with Captive _ Tanks
as shown in Figure 2.
For mounting pump to tank, purchase tank fitting Kit
No. 2788.
CRAFTSMAN Captive Air* Tanks are precharged with
air at the factory. Check the tank Owner's Manual to
find if air charge needs adjustment. Your pump re-
quires 30 pounds for proper operation.
The jet pump can also be mounted on standard hori-
zontal tanks. A kit consisting of all necessary piping, el-
bows, and other fittings, is furnished with the tank for
mounting pump using this method. See Figure 3.
Instructions are included with tank.
Air Volume Control -
Included With Standard Horizontal Tank
There is a 1-1/4" x 1/4" reducer bushing and a 1/4" x 1-1/2"
nipple supplied in the fittings package. Use the one that fits
into the air volume control tapping in the end of the tank
as shown in Figure 3. Use pipe compound on male threads.
Screw the air volume control on to the 1/4" fitting and the
right angle compression fitting into the bottom tapping of
the air volume control.
Remove the 1/4" pipe plug, Key No. 13, Page 10, on
the jet portion of the pump body near the check valve.
Insert a 1/4" compression fitting into this tapping. Cut
tubing to length and assemble the two fittings in the
air volume control and pump body. Use nuts, sleeves,
and inserts furnished.
Priming the Pump
I_' CAUTIONI Never run pump dry. Running pump
without water may cause pump to overheat, dam-
aging seal and possibly causing burns to persons
handling pump. Fill pump with water before starting.
[AWA_ Never run pmnp against closed dis-
charge. To do so can boil water inside pump,
causing hazardous pressure in unit, risk of ex-
plosion and possibly scalding persons handling
pump.
DO NOT START MOTOR UNTIL PUMP HAS BEEN
FILLED WITH WATER.
1. Remove the priming plug. fill pump with water.
Replace priming plug. If a priming tee and plug
have been provided at the well head for a long hor-
izontal run, be sure this tee is filled and the plug re-
placed, using pipe compound on plug threads. See
Figure 1, Page 3.
2. Start the pump. Water win be pumped in a few min-
utes; the time depending upon the depth to water,
and the distance of horizontal run. If pump does
not prime, check for a possible leak on the suction
side of the pump. Reprime. Check to be sure suc-
tion lift - distance from water level to pump - does
not exceed 20 feet.